13 Forming
If a unit has been non-operational for more than one year, the DC link
capacitors have to be newly formed. If this is not carried out, the unit
can be damaged when the line voltage is powered up.
If the unit was started-up within one year after having been
manufactured, the DC link capacitors do not have to be re-formed. The
date of manufacture of the unit can be read from the serial number.
(Example: A-J60147512345)
Digit Example Significance
1 and 2 A- Place of manufacture
3H
J
K
1996
1997
1998
4 1 to 9
O
N
D
January to September
October
November
December
5 to 14 Not relevant for forming
The following applies for the above example:
Manufacture took place in June 1997.
During forming, the DC link of the unit is connected up via a rectifier, a
smoothing capacitor and a resistor.
As a result, the DC link capacitors receive a defined voltage and a
limited current, and the internal conditions necessary for the function of
the DC link capacitors are restored.
Motor-
connection
U2/T1
V2/T2
W2/T3
PE2
DC link
U1/L1
V1/L2
W1/L3
Inverter
C / L+ D / L-
PE1
Disconnect
AC R
Forming
3AC
Pre-charging
Rectifier
Fig. 13-1 Forming circuit